Add temperature, voltage, current, pressure and other data inputs to the 840, 850 or 890 Series of Fuel Cell Test Systems: Our 892e multichannel data collection system for up to 16 additional channels of voltage and/or temperature measurement with SAI's line of Turn-Key Fuel Cell Test Systems. The 892e is ideal for inlet/outlet pressure sensors, inlet/outlet cooling, or distributed stack temperatures, among others. Contact us for configuration information.

 

The Model 892e Data Expansion Subsystem is a hardware component intended to increase the input capabilities of the 850C/e and 890C/CL/e series of fuel cell test systems. The Model 892e is configured with two factory-installed eight-channel data acquisition modules, each of which is factory-configured for one of several input types.

Features:

  • Remote operation from RS485 interface of 840, 850C/e, 890C/CL/e, and 857 series test systems.
  • 8 thermocouple inputs with cold junction compensation using miniature thermocouple connectors
  • 8 Voltage or Current inputs using circular locking connector with cable wired for voltage transducer, current transducer or general analog input
  • Pass-through RS485 connector for use with other accessory equipment
  • 2U 19” rack-mount enclosure
  • Supported by FuelCell®, and FlowCell™ software directly

 

 892e

Specifications:

Number of Channels: 16 (differential) Input Types: 8 Thermocouple + 8 mV, V, or mA
Input Voltage Ranges: ±150 mV, ±500 mV, ±1 V, ±5 V, ±10V Voltage Accuracy: ±0.1% of full-scale
Input Current Range: ±20 mA (using 125 Ω, 0.1% resistor) Current Accuracy: ±0.1% of full-scale
Voltage, Current Resolution: 0.01 % of full scale AC Noise Rejection (50/60Hz): Common Mode: 120 VAC
Input Over-voltage Protection: ±35 V Input Impedance (differential): 2E+7 Ω or greater
Max. Voltage Difference on ±10 V for ±5 V and ±10 V ranges, ±2.5 V for other ranges  
8-Channel Group:
  • Temperature Accuracy: ±0.5 °C at 0 °C
  • Temperature Resolution: 0.01 °C
  • Power Requirement: 100-240 V, 50/60Hz, 0.3A (Auto Voltage Select)
  • Operating Temperature: 0 - 40 °C
  • Physical Dimensions: 2U rack-mount, 9 cm H x 48 cm W x 20 cm D (3.5 in. H x 
    19 in. W x 8 in. D)
Thermocouple Types:
  • J (-210 to 760 °C)    K (-270 to 1,372 °C)
  • T (-270 to 400 °C)    E (-270 to 1,000 °C)
  • R (0 to 1,768 °C)     S (0 to 1,768 °C)
  • >B (0 to 1,820 °C)     C (0 to 2,320 °C)

 


Download the 892e Datasheet

Scribner Associates Inc.

Is a leading developer of high-quality instrumentation and software for the electrochemical research and development (R&D) community. Scribner Associates’ hardware and software products are used by academic, private and government laboratories in the areas of fuel cell development and evaluation, battery and redox flow cell technology, corrosion science and engineering, electrochemical sensors and multi-electrode arrays.

Read more

Contact Us

  150 East Connecticut Avenue
      Southern Pines, North Carolina, USA 28387

  +1-910-695-8884
  +1-910-695-8886
  info@scribner.com